Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Rev. Col. Bras. Cir ; 49: e20223177, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1376237

ABSTRACT

ABSTRACT Objective: The goal of this study is to verify how commercially available pre-contoured superior plates fit on clavicle midshaft fractures. Methods: 100 cadaveric clavicles were evaluated by three distinct observers applying the clavicle congruence score and comparing four different 6 to 8-hole pre-contoured anatomic locking-plate systems. Results: the inter-observer agreement was considered moderate by the percentage agreement and fair by the Fleiss' Kappa, with no significant differences between evaluations. Only 1 of the 8 plates presented an anatomic fit greater than 70%. Long plates (8 holes) presented a poor fit compared to short plates (6 or 7 holes). Conclusions: the overall evaluation showed that currently-available pre-contoured superior plate systems provide a poor fit on clavicles for midshaft fracture fixations. Long plates present a worse fit compared to short ones.


RESUMO Objetivo: verificar como as placas superiores pré-moldadas disponíveis no mercado se adaptam às fraturas do terço médio da clavícula. Método: 100 clavículas de cadáveres foram avaliadas por três observadores distintos, aplicando-se o escore de congruência da clavícula e comparando quatro sistemas diferentes de placas bloqueadas anatômicas pré-moldadas de seis a oito furos. Resultados: a concordância interobservador foi considerada moderada pelo percentual de concordância e regular pelo índice Kappa de Fleiss, sem diferenças significativas entre as avaliações. Apenas uma das oito placas apresentou encaixe anatômico maior que 70%. As placas longas (oito furos) apresentaram um encaixe ruim em comparação com as placas curtas (seis ou sete furos). Conclusões: os sistemas de placa superior pré-moldadas disponíveis atualmente fornecem um encaixe inadequado às clavículas para fixações de fraturas do terço médio. Placas longas apresentam um encaixe pior que as curtas.

2.
Acta ortop. bras ; 20(6): 329-333, nov.-dez. 2012. ilus
Article in Portuguese | LILACS | ID: lil-660194

ABSTRACT

OBJETIVO: Estudar o desfecho de fraturas subtrocantéricas de quadril tratadas com placa de bloqueio lateral da parte proximal do fêmur. MÉTODO: Revisamos retrospectivamente os resultados clínicos de 48 casos de fraturas subtrocantéricas tratadas com placas de bloqueio lateral da parte proximal do fêmur de janeiro de 2008 a maio de 2010. Registrou-se o progresso da consolidação da fratura, assim como a ocorrência de complicações. A função da articulação do quadril foi avaliada pelo índice social de Harris e o escore de mobilidade de Parker-Palmer, um ano após a cirurgia. RESULTADO: Quarenta e cinco pacientes foram acompanhados até a união da fratura ou a revisão da cirurgia. Entre os 45 pacientes, 43 atingiram a união da fratura sem outra intervenção. Trinta e oito fraturas consolidaram sem perda da posição no acompanhamento de um ano. Não houve casos de perfuração da cabeça do fêmur pelo parafuso. O escore médio do índice social de Harris foi 86,5 ± 9,8 (73 ~95). A média do escore de mobilidade de Parker e Palmer foi 7,4 ± 2,1 (3~ 9). CONCLUSÃO: A placa de bloqueio lateral da parte proximal do fêmur é o tipo de fixação interna estável e efetiva para tratar as fraturas subtrocantéricas de quadril e tem a vantagem de fixação estável, em especial em fratura da parede lateral do fêmur. Nível de evidência IV, Série de Casos.


OBJECTIVE: To study the outcome of subtrochanteric hip fractures treated by using a proximal lateral femur locking plate. METHOD: We retrospectively reviewed the clinical results of 48 cases of femoral subtrochanteric fractures treated with proximal lateral femur locking plates from Jan 2008 to May 2010. The progress of fracture healing, as well as the occurrence of complications, was recorded. The function of the hip joint was evaluated by Harris social index and the Parker and Palmer mobility score at 1 year after the operation. RESULT: 45 patients were followed up until fracture union or a revision surgery. Among the 45 patients, 43 patients obtained fracture union without further intervention. 38 fractures healed with no loss of position at the 1-year follow-up. There were no cases of hip screw cutting through the femoral head. The mean score of Harris social index was 86.5±9.8 (73~95). The mean Parker and Palmer mobility score was 7.4±2.1 (3~9). CONCLUSION: The proximal lateral femur locking plate is the kind of stable and effective internal fixation of treating subtrochanteric hip fractures which has the advantage of stable fixation especially for the lateral femoral wall fracture. Level of Evidence IV, Case Series.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged, 80 and over , Hip Joint/surgery , Bone Plates , Fracture Fixation, Internal , Femoral Fractures/surgery , Femoral Fractures/rehabilitation , Hip Fractures/surgery , Hip Fractures/rehabilitation , Fractures, Bone/classification , Radiography
3.
Acta ortop. bras ; 20(4): 223-225, 2012. tab
Article in Portuguese | LILACS | ID: lil-644434

ABSTRACT

OBJETIVO: Avaliamos o tratamento da pseudoartrose de fratura diafisária do úmero com placa de compressão dinâmica de janeiro de 2002 a dezembro de 2009. MÉTODOS: Vinte e dois pacientes foram tratados durante o período do estudo. O trauma foi a causa predominante de lesão em 86,4% dos pacientes. RESULTADOS: A pseudoartrose foi atrófica em 81,8% e hipertrófica em 18,2% dos indivíduos. Havia lesão primária do nervo radial nervo em 27,3% dos pacientes. Todos os participantes tinham fratura fechada à apresentação e 81,2% deles tinham recebido tratamento anterior de traditional bone setters (pessoa que faz a redução de ossos quebrados ou deslocados, geralmente sem ser médico licenciado) e 18,8% tinham falha do tratamento conservador com gesso. O tempo médio até a união foi 16 semanas. O tratamento anterior com traditional bone setters afetou significantemente o tempo de consolidação da fratura (p < 0,05). Todas as fraturas tiveram consolidação bem-sucedida. CONCLUSÃO: Concluímos que o uso de placa de compressão dinâmica continua a ser uma opção eficaz de tratamento da pseudoartrose de fratura diafisária do úmero. Nível de evidência III, Estudo retrospectivo.


OBJECTIVE: We evaluated the treatment of nonunion of humeral shaft fracture with dynamic compression plate from January 2002 to December 2009. METHODS: Twenty two patients were treated over the study period. Trauma was the predominant cause of injury in 86,4% of the patients. RESULTS: Nonunion was atrophic in 81,8% and hypertrophic in 18,2% of the individuals. There was a primary injury of the radial nerve in 27,3% of the patients. All the participants had closed fracture at presentation, and 81,2% had received previous treatment from traditional bone setters and 18,8% had failure of the conservative cast management.The average time to healing was 16 weeks. Previous treatment from traditional bone setters significantly affected the time to fracture healing (p<0,05). All fractures had successful union. CONCLUSION: It was concluded that dynamic compression plating remains an effective treatment option for nonunion of humeral shaft fracture. Level of Evidence III, Retrospective study.


Subject(s)
Humans , Male , Female , Bone Plates , Fracture Fixation, Internal , Humeral Fractures/surgery , Humeral Fractures/therapy , Pseudarthrosis/therapy , Accidents, Traffic , Radiography
SELECTION OF CITATIONS
SEARCH DETAIL